Onkyo (and its Integra sibling) use ISCP / eISCP — Integra Serial Control Protocol wrapped for Ethernet — on TCP/UDP 60128. Each eISCP frame is a 16-byte header followed by an ASCII command such as MVLUP or SLI26. The receiver replies with the actual resulting state, which is why the app can show a real volume level rather than an optimistic guess.

What you can control

Set it up

1

Enable Network Standby

On the receiver: Setup → Hardware / Network → Network Standby. The eISCP listener must survive standby.

2

Install Remote97 on the same LAN

Get it from the download page.

3

Discover or add the IP

Remote97 probes port 60128 across the selected subnet; manual IP add works too when multicast is filtered.

4

Use status feedback

Because eISCP answers with the resulting state, volume and input shown in the app stay in sync with the front panel.

Honest limitations and troubleshooting

First power-on needs the real remote. A receiver in deep standby has no live network stack. Network Standby keeps it reachable for subsequent commands, but the initial power-on after a full unplug is a hardware action.